How Many Amps Does an Electric Dryer Use?

A 5000W electric dryer at 240V draws 20.83 amps and needs a dedicated 30A circuit.

Electric Dryer Amps Explained

A standard electric clothes dryer draws 5000 watts at 240V, which is 20.83 amps. The NEC requires a dedicated 30A double-pole breaker and 10 AWG copper wire for electric dryer circuits, using the same 4-wire or 3-wire NEMA 14-30 or 10-30 receptacle depending on the age of the installation. Gas dryers, by contrast, only need a standard 120V outlet for their control electronics and drum motor, drawing under 5 amps.

Frequently Asked Questions

How do I convert watts to amps?

For DC circuits, divide watts by volts (Amps = Watts ÷ Volts). For AC single-phase circuits, divide watts by the product of power factor and volts. For AC three-phase circuits, divide watts by the product of √3, power factor, and volts.

Why do I need power factor for AC calculations?

Power factor accounts for the phase difference between voltage and current caused by inductive loads like motors and compressors. Purely resistive loads (heaters, incandescent bulbs) have a power factor of 1.0. Motors typically run 0.8–0.95.

What breaker size do I need for a 1500W appliance at 120V?

1500W at 120V draws 12.50 amps. Per NEC Article 210.20, continuous loads must not exceed 80% of a breaker rated capacity, so a 15A breaker (12A max continuous) is not sufficient. A dedicated 20A circuit is required.

Does this calculator work for 240V appliances?

Yes. Enter your wattage and set voltage to 240V for dryers, water heaters, ranges, and EV chargers. At the same wattage, 240V circuits draw half the current of 120V circuits.

Is this calculator accurate for 3-phase industrial power?

Yes. Select the AC 3-Phase tab, enter your line voltage (commonly 208V or 480V), and choose line-to-line or line-to-neutral mode. The calculator uses the precise value of √3, not a rounded 1.732 approximation.

Can I use this to size wire gauge?

The calculator provides an AWG wire gauge recommendation based on NEC Table 310.15(B)(16) for 60°C copper conductors. Always confirm final wire and breaker sizing with a licensed electrician before installation.